Thick-film ceramic measuring cell

Principle of thick-film ceramic measuring cell

Unlike the thin-film strain gauge method, the Wheatstone bridge is bonded directly to a ceramic diaphragm in this case. Flexure of the diaphragm as the result of the external pressure causes a change in the resistances of this Wheatstone bridge, which is converted to a pressure-proportional signal.